Forearm Head Support Reduces Dental Contact During Direct Laryngoscopy in Trial

Forearm Head Support Reduces Dental Contact During Direct Laryngoscopy in Trial

A novel direct laryngoscopy technique that maintains head extension using the practitioner’s left forearm or elbow to support the patient’s forehead significantly reduced dental contact compared with the conventional technique, according to a single-centre randomized crossover trial published in the Canadian Journal of Anesthesia. Conducted by researchers at Seoul National University Hospital in 84 adult patients undergoing elective surgery under general anesthesia, the trial evaluated whether physical forehead support could decrease contact with the maxillary central incisors, a primary mechanical precursor to traumatic dental injury. The primary outcome demonstrated that dental contact occurred in 44 of 84 patients (52%) when using the novel forearm-support technique, compared with 65 of 84 patients (77%) under the conventional laryngoscopy method. This difference represented a statistically significant relative risk of 0.68 with a 95% confidence interval of 0.57 to 0.80 and a P value less than 0.001, without period effects (P = 0.90) or carryover effects (P = 0.71).

The forearm maneuver also produced significant improvements across secondary geometric and visual outcomes. The blade-to-tooth distance, measured as the shortest vertical separation between upper incisors and the laryngoscope blade using a ruler, was significantly longer with the novel technique than with conventional laryngoscopy, showing a median difference of 0 mm with an interquartile range of 0 to 1 mm (P = 0.001). The angle of head extension averaged 22.9° with a standard deviation of 7.7° for the novel technique, compared with 18.4° with a standard deviation of 7.6° for the conventional technique, yielding a mean difference of 4.5° with a 95% confidence interval of 2.1 to 6.8 and a P value less than 0.001. In 74 patients (88%), the extension angle achieved with the novel technique exceeded that of the conventional approach. Attending anesthesiologists also reported superior glottic visualization via the percentage of glottic opening score, with median values of 5 versus 4, a median difference of 1 (P = 0.003), and high satisfaction scores of 4 or 5 in 89% versus 73% of attempts (P = 0.01).

Traumatic dental injury is recognized as a frequent clinical complication associated with tracheal intubation, often occurring when the rigid blade of a direct laryngoscope levers against or impinges upon the maxillary incisors during visualization of the vocal cords. To evaluate whether practitioner forearm support could mitigate this hazard without requiring external assistance or specialized devices, investigators established a clinical trial protocol approved by the Institutional Review Board of Seoul National University Hospital under approval number H-1711-094-901 on January 22, 2018. The study was registered at ClinicalTrials.gov under identifier NCT05495880, with its initial registration submission dated August 8, 2022. The clinical research adhered strictly to the ethical principles of the Declaration of Helsinki and followed the Consolidated Standards of Reporting Trials guidelines throughout its preparation. Furthermore, written informed consent was obtained from all participating patients prior to surgery.

Between July 2023 and February 2024, the study team assessed 95 adult surgical patients aged 18 years and older who were scheduled for elective operations requiring tracheal intubation under general anesthesia. Eleven patients were excluded prior to randomization based on specific anatomical, dental, and medical exclusion criteria: seven had loose teeth, two had unstable temporary teeth or partial dentures, and two had a documented medical history of difficult tracheal intubation. Additional predefined exclusion criteria included cervical spine injury or pathology, absence of teeth, periodontitis, oral abscess, craniofacial anomalies, need for rapid sequence induction, or refusal to participate. The remaining 84 patients were randomized and completed the dual-technique protocol without any dropouts. Over the course of the study, no participant experienced unexpected difficult intubation, difficult manual ventilation, or episodes of oxygen desaturation during the procedures.

Upon entering the operating room, each patient underwent an initial airway and dental assessment in a seated position performed by an attending anesthesiologist. This preanesthetic evaluation recorded the modified Mallampati classification, the mandibular protrusion test, the interincisor gap measured in millimeters with the mouth fully opened, and the thyromental distance measured in millimeters with the mouth closed and the head fully extended. Patients were subsequently placed in a supine position with their head supported by a standardized seven-centimeter-high pillow. Baseline neck mobility was quantified before general anesthesia by determining the maximum degree of neck extension, calculated as the angular difference between neutral and fully extended neck postures using a digital BevelBox inclinometer securely attached to the glabella. Before pharmacological induction, standard physiological monitoring was initiated with pulse oximetry, electrocardiography, and noninvasive blood pressure tracking.

After preoxygenation, general anesthesia was induced with an intravenous bolus of propofol at 1.5 to 2 mg/kg and continuous target-controlled infusion of remifentanil at an initial effect-site concentration of 3.0 ng/mL. Upon loss of consciousness, manual ventilation was initiated, and neuromuscular monitoring commenced using a TwitchView device placed on the ulnar nerve at the wrist. Patients then received rocuronium at 0.6 to 0.8 mg/kg intravenously to facilitate tracheal intubation, while anesthesia depth was maintained with sevoflurane targeting a Bispectral Index between 40 and 60. The experimental laryngoscopy sequence commenced only after complete neuromuscular blockade was verified by a train-of-four count of zero. Immediately following the first laryngoscopy attempt, the patient’s head was returned to a neutral position to prevent mechanical carryover effects, and tracheal tube insertion was deliberately performed only after the second laryngoscopy to minimize mucosal and tracheal trauma.

Direct laryngoscopy was executed by two attending anesthesiologists who lacked prior experience with the novel technique, using a classic Macintosh blade of size 3 or 4 selected on the basis of patient sex. In both maneuvers, the clinician initially maximally extended the patient’s head with their right hand (designated position T1), aligned the laryngoscope in the left hand along the midline, and lifted upward and forward along the handle axis to visualize the glottis (position T2). Under the conventional technique, the right hand was released, and glottic exposure was sustained solely through the force of the left hand holding the laryngoscope (position T3C). Under the novel technique, the operator supported the patient’s forehead with their left forearm or elbow to maintain head extension before releasing the right hand (position T3N). While maintaining T3C or T3N, a dedicated research nurse recorded maxillary incisor dental contact, measured blade-to-tooth distance with a Mitutoyo ruler, and documented head extension angle with the digital BevelBox. Safety protocols mandated pausing the procedure and administering 100% mask oxygenation if peripheral oxygen saturation dropped below 90% until it reached above 98%, though no participant required desaturation pauses.

Sequence allocation was randomized using R software version 4.2.0 with a block size of two, with results concealed in sealed opaque envelopes opened immediately prior to anesthesia induction by a nurse not involved in the study. Power calculations were based on an expected 95% dental contact rate with conventional laryngoscopy, with investigators hypothesizing that forearm support would reduce contact to 75%, an absolute reduction of approximately 20%. Assuming a conservative 30% discrepancy rate for McNemar’s test, an initial target of 75 participants provided 90% power at a two-sided alpha level of 0.05, which was expanded to 84 patients to accommodate an anticipated 10% dropout rate. Statistical analyses were completed using R version 4.3.3. Categorical comparisons utilized McNemar’s test, presenting relative risks and 95% confidence intervals. Continuous data were assessed with paired t-tests or Wilcoxon signed-rank tests according to distribution normality determined by the Shapiro–Wilk test, with non-normally distributed metrics evaluated via nonparametric percentile bootstrap estimation across 1,000 repetitions, and mixed modeling confirming the absence of period or carryover effects.

Comparing their results with existing airway strategies, the authors observed that previous modifications designed to protect maxillary teeth—such as Bizzarri–Giuffrida, Callander, or Improved Vision Macintosh blades—can impair tongue control or blade rotation, while dental guards and adhesive flange pads can restrict intraoral volume, impair direct visualization, or fail against levering forces while adding financial and environmental costs. Although forearm support reduced contact frequency by approximately 25% without auxiliary equipment, its 52% contact rate was higher than the 36% observed in an earlier study where an assistant maintained head extension. The authors attributed this difference to a higher proportion of patients with limited mandibular protrusion, the inability of forearm counterpressure to completely prevent head extension release (a 4.5° extension gain versus 6.6° with dedicated assistance), and operator unfamiliarity during initial implementation.

The researchers highlighted several methodological and anatomical limitations of their investigation. Operator upper extremity length may influence technical performance because the practitioner’s left arm must simultaneously elevate the laryngoscope and push down upon the patient’s forehead. Furthermore, dental contact force was not measured, nor was the actual occurrence of traumatic dental injury directly evaluated due to its low baseline clinical incidence. Forehead compressive pressure was also unmeasured, warranting caution regarding theoretical risks to facial bones, orbits, skull structures, or the cervical spine in patients with preexisting trauma or reconstructive surgery. In addition, the study cohort presented relatively low body mass indices with airways primarily classified as Mallampati class 1 or 2, limiting generalizability to patients with obesity or anticipated difficult airways.

Subject of Research: Forearm support technique to reduce dental contact during direct laryngoscopy

Article Title: Forearm support to reduce dental contact during direct laryngoscopy: a randomized crossover trial

Article References: Song, S. E., Ju, J.-W., Park, J. Y., Park, D., Yoon, S., Nam, K., Lee, H.-J., Seo, J.-H., Kim, W. H., & Bahk, J.-H. (2025). Forearm support to reduce dental contact during direct laryngoscopy: a randomized crossover trial. Canadian Journal of Anesthesia/Journal canadien d’anesthésie, 72(10), 1511-1520. https://doi.org/10.1007/s12630-025-03035-w

Image Credits: AI Generated

DOI: 10.1007/s12630-025-03035-w

Keywords: direct laryngoscopy, tracheal intubation, dental contact, traumatic dental injury, head extension, forearm support, randomized crossover trial, blade-to-tooth distance, glottic opening, POGO score, Macintosh blade, airway management, anesthesia induction, elective surgery, neuromuscular monitoring, Seoul National University Hospital, nonoperating room anesthesia