In a retrospective dosimetric evaluation of stereotactic centralized ablative radiation therapy for bulky lung tumors, researchers found that dynamic conformal arc therapy matched volumetric modulated arc therapy in tumor core coverage while significantly reducing treatment time and monitor units. The study examined twenty treatment plans created for ten patients with large thoracic malignancies exceeding five centimeters in diameter. Investigators found that both rotational arc techniques achieved clinical target benchmarks, delivering fifty-four gray in three fractions to the central tumor core. However, volumetric modulated arc therapy provided superior dose protection immediately outside the tumor, demonstrating significantly lower maximum peripheral doses and reduced low-dose lung exposure. Conversely, dynamic conformal arcs reduced treatment delivery time by roughly thirty-five seconds per session and required nearly nine hundred and thirty fewer monitor units. These results highlight dynamic conformal arc therapy as a fast, practical option for patients unable to endure prolonged treatment sessions.
Bulky volume tumors represent a major clinical challenge in radiation oncology because conventional therapies often fail to achieve local control, restricting advanced-stage patients to palliative management. Standard fractionated radiotherapy cannot completely destroy large tumors without causing extensive collateral damage to surrounding healthy organs. Although stereotactic body radiation therapy and stereotactic radiosurgery deliver ablative doses to small lesions, their clinical application to massive lesions remains severely constrained by normal tissue toxicity. Spatially fractionated radiation therapy overcomes this limitation by shifting away from homogeneous target dosing. Instead of uniform exposure, spatial fractionation delivers multiple concentrated high-dose hotspots within the tumor mass, generating steep peak-to-valley dose ratios that induce tumor apoptosis and trigger anti-tumor immune responses. Stereotactic centralized ablative radiation therapy combines the principles of lattice spatial fractionation with stereotactic body radiotherapy. By placing a single enlarged ablative hotspot within the tumor geometric center, this approach preserves surrounding normal tissues while concentrating ablative radiation inside the core.
Because the target volume in stereotactic centralized ablative radiation therapy sits at the tumor core away from normal tissue borders, the high-dose hotspot can be enlarged without escalating collateral damage. While clinically established for stereotactic treatments of spherical lesions, dynamic conformal arcs had never been evaluated for centralized core ablation. The current study systematically investigated whether dynamic conformal arcs can fulfill core ablation criteria on modern linear accelerators and dosimetrically compared its performance against volumetric modulated arcs in bulky tumors.
The research team retrospectively analyzed ten patients with bulky lung tumors treated between 2022 and 2024, producing twenty comparative plans. Eligible participants were adults with surgically unresected lung tumors approved for radiotherapy by the hospital ethics committee, presenting with lesions exceeding five centimeters in maximum diameter and volumes over one hundred and fifty cubic centimeters. CT simulation utilized an integrated CT-linac with five-millimeter slice thickness, scanning at least fifteen centimeters beyond the tumor in all directions. Intelligent contouring generated organs at risk with manual physician verification. The gross tumor volume represented the entire radiographic lesion, within which clinicians delineated a centrally located stereotactic core target volume. Across all cases, median gross tumor volume measured 344.56 cubic centimeters, while median core target volume measured 20.73 cubic centimeters, yielding a median volume ratio of 7.06 percent.
Treatment planning was performed on the uRT-TPOIS system utilizing six-megavolt flattening-filter-free beams with a dose rate of twelve hundred monitor units per minute and a convolution calculation algorithm. The calculation grid was set at 2.5 millimeters to align with the five-millimeter CT thickness. Both modalities used dual 360-degree coplanar arcs with a zero-degree couch angle, rotating clockwise and counterclockwise at collimator angles of ten and 350 degrees. Based on clinical trial dosing, the prescription delivered fifty-four gray across three fractions of eighteen gray each, targeting the central core volume. Planning constraints prioritized target minimum dose and dose-volume criteria, applying an auxiliary ring with a five percent drop-off ratio at zero millimeters. An additional annular ring two centimeters beyond the tumor margin enforced a maximum total dose ceiling of one thousand centigray. Target coverage protocols omitted uniform dose normalization once all coverage thresholds were satisfied, ensuring direct dosimetric comparability between the resulting plans.
Target volume requirements dictated that eighty percent of prescription dose cover at least ninety-five percent of the core volume, twenty percent cover over ninety percent of gross tumor volume, and the coverage ratio exceed 4.5 percent. Organ-at-risk evaluation followed American Association of Physicists in Medicine Task Group 101 guidelines for three-fraction treatments. Lung constraints required volumes receiving twelve point four gray or less to exceed one thousand cubic centimeters, and volumes receiving eleven point six gray or less to exceed fifteen hundred cubic centimeters. Maximum dose limits capped the esophagus at 25.2 gray, great vessels at forty-five gray, heart and trachea at thirty gray, ribs at 36.9 gray, and spinal cord at 21.9 gray. Normal tissue outside the tumor was evaluated for maximum dose and volume receiving over five gray per fraction. Paired statistical analyses utilized Wilcoxon signed-rank tests with Holm multiple-comparison adjustments.
Both planning techniques fully met target coverage thresholds across all ten patients. Dynamic conformal arc plans achieved median gross tumor volume coverage of 90.71 percent at twenty percent prescription dose, compared to 93.64 percent for volumetric modulated arcs, though this difference became non-significant after Holm adjustment. Eighty percent prescription coverage within the gross tumor reached medians of 10.69 percent in dynamic conformal plans and 10.54 percent in modulated plans, with coverage ratios of 11.80 percent and 11.11 percent. Within the centralized core volume, median coverage of eighty percent prescription dose was 99.02 percent for dynamic conformal arcs and 99.98 percent for modulated arcs. Conformity index medians were 0.88 for dynamic conformal arcs and 0.86 for volumetric modulated arcs. Homogeneity index medians were 0.81 and 0.79, gradient index medians were 4.21 and 4.12, and peak-to-valley dose ratios were 2.38 and 2.55, indicating that both arc strategies achieve comparable dose distributions within centralized target cores.
Despite equivalent target coverage, volumetric modulated arc therapy demonstrated superior control over radiation spillover into adjacent normal tissues outside the gross tumor margin. The median maximum per-fraction dose outside the gross tumor was 7.45 gray in dynamic conformal plans compared to 6.18 gray in modulated plans, representing a statistically significant adjusted increase of 1.30 gray for conformal delivery. Volumetric modulated arc plans satisfied the five-gray ceiling in four cases, whereas no dynamic conformal plan achieved this target. Furthermore, the volume of normal tissue receiving greater than five gray per fraction was significantly higher in dynamic conformal plans, recording a median of 16.51 cubic centimeters versus 2.93 cubic centimeters for modulated plans. Nine modulated plans kept this volume below twenty cubic centimeters, compared to six conformal plans. Total lung volume outside the gross tumor receiving five gray was also significantly lower under modulated delivery, showing a median of 11.36 percent compared to 12.53 percent for dynamic conformal arcs.
Dynamic conformal arc planning demonstrated clear advantages in delivery efficiency, recording fewer monitor units and faster treatment delivery times. Dynamic conformal arcs required a median of 3519.64 monitor units compared to 4206.42 units for volumetric modulated arcs, yielding a mean paired reduction of 929.50 monitor units. Conversely, critical thoracic organs including the esophagus, heart, trachea, spinal cord, ribs, and great vessels showed no statistically significant dose differences between techniques after adjustment. Because healthy lung volume receiving five gray represents only a small fraction of total lung capacity, and distant organs sit well beyond the five-gray threshold, both techniques maintained organ doses within safe stereotactic body radiotherapy constraints.
The authors highlighted several methodological limitations that characterize this initial evaluation and delineate directions for future research. The investigation was conducted at a single institution using a retrospective cohort of ten patients, a single treatment planner, and one integrated CT-linac system with a convolution dose algorithm. In addition, the study evaluated a single prescription of fifty-four gray across three fractions without exploring respiratory gating or abdominal compression, and physical delivery quality control was not examined. Future investigations will seek to expand patient cohorts across multiple institutions, examine other cancer sites, and test escalated fraction doses reaching twenty-four gray or higher. In conclusion, dynamic conformal arc therapy offers a feasible, efficient approach for stereotactic centralized ablative radiation therapy, significantly reducing treatment duration and monitor units while preserving core target coverage. However, when large tumors display irregular shapes or sit adjacent to critical organs where strict peripheral dose limits are essential, volumetric modulated arc therapy remains the superior clinical choice.
Subject of Research: Dosimetric comparison of dynamic conformal arc and volumetric modulated arc therapy in stereotactic centralized ablative radiation therapy for bulky lung tumors
Article Title: Stereotactic centralized/core ablative radiation therapy: a dosimetric evaluation of dynamic conformal arc and volumetric modulated arc therapy
Article References: Wang, Y., Xu, D., Liu, Y., & Yu, L. (2026). Stereotactic centralized/core ablative radiation therapy: a dosimetric evaluation of dynamic conformal arc and volumetric modulated arc therapy. Journal of Radiation Research and Applied Sciences, 19(4), Article 102844. https://doi.org/10.1016/j.jrras.2026.102844
Image Credits: AI Generated
DOI: 10.1016/j.jrras.2026.102844
Keywords: stereotactic centralized ablative radiation therapy, dynamic conformal arc therapy, volumetric modulated arc therapy, spatially fractionated radiation therapy, bulky lung tumors, dosimetric evaluation, gross tumor volume, stereotactic core target volume, organs at risk, monitor units, treatment delivery time, radiation oncology, hypofractionated radiotherapy, flattening filter-free, CT-linac, Wilcoxon signed-rank test, dose conformity