d-dimer-alone-cannot-safely-rule-out-acute-aortic-dissection-in-imaging-cohort
D-Dimer Alone Cannot Safely Rule Out Acute Aortic Dissection in Imaging Cohort

D-Dimer Alone Cannot Safely Rule Out Acute Aortic Dissection in Imaging Cohort

In a retrospective single-center evaluation of emergency vascular imaging, standalone D-dimer testing did not provide sufficient diagnostic safety to rule out acute aortic dissection on its own. The study, conducted by researchers Reşad Beyoğlu and Duygu Durmaz from Bandırma Onyedi Eylül University in Türkiye, evaluated diagnostic accuracy and clinical risk scores among patients referred for computed tomography angiography. The investigators found that relying exclusively on negative biomarker results leaves a persistent residual risk of missed disease, particularly in settings where blood sampling times relative to symptom onset are not strictly standardized.

Acute aortic dissection is a severe cardiovascular condition that frequently presents without classical high-risk clinical features, presenting substantial diagnostic hurdles for emergency medical teams during initial evaluation. To determine how clinical scoring systems perform in real-world practice, the investigators set out to assess the distribution of the Aortic Dissection Detection Risk Score among patients with confirmed dissection. Concurrently, the research team analyzed the diagnostic performance of D-dimer testing within a defined case-control cohort referred for advanced thoracoabdominal imaging.

The study design utilized a retrospective nested case-control framework reviewing 12,036 thoracoabdominal computed tomography angiography examinations completed between October 1, 2014, and July 1, 2026. From this multi-year imaging archive, the investigators identified 178 patients with imaging-confirmed acute aortic dissection. To provide a comparative assessment of laboratory markers, the authors randomly selected 356 comparison patients from the same imaging registry, evaluating D-dimer classifications based on contemporaneous institutional reference ranges in place at the medical center.

A primary focus of the investigation was the retrospective reconstruction of the Aortic Dissection Detection Risk Score among the 178 confirmed cases. The authors determined that low risk scores were widespread across the disease cohort, with 79 of the 178 confirmed acute aortic dissection patients, representing 44.4 percent, scoring either 0 or 1 on the risk instrument. Because risk scores were not recorded or reconstructible for the 356 comparison patients, the researchers noted that the combined strategy of integrating risk scoring with D-dimer testing could not be directly validated in this sample.

Analysis of D-dimer laboratory performance across the case-control group demonstrated a diagnostic sensitivity of 90.45 percent and a specificity of 64.89 percent. These operating characteristics corresponded to a positive likelihood ratio of 2.58 and a negative likelihood ratio of 0.15. Using Bayesian statistical methods, the authors estimated that following a negative D-dimer result, the post-test probability of acute aortic dissection remained 0.77 percent when assuming a low pretest probability of 5 percent, 1.61 percent at an assumed 10 percent pretest probability, and 3.55 percent at an assumed 20 percent pretest probability.

The dataset also revealed notable vulnerabilities among false-negative biomarker findings. Across the 17 confirmed dissection cases with negative D-dimer results, none of the patients had an Aortic Dissection Detection Risk Score of 0, while seven patients had a score of 1. These seven patients who presented with both a low risk score of 1 and a negative biomarker reading accounted for 3.9 percent of all 178 confirmed dissection cases in the study cohort, illustrating how false reassurance could arise when interpreting test results in isolation.

The authors concluded that within this retrospective cohort referred for computed tomography angiography, D-dimer alone failed to provide adequate standalone rule-out performance for acute aortic dissection. However, they emphasized that these findings should not be interpreted as evidence against obtaining D-dimer measurements when blood samples are collected within appropriate early diagnostic timeframes and applied within a validated clinical algorithm. Because combined risk-scoring and biomarker protocols remain unvalidated in this dataset, the researchers called for prospective multicenter studies to assess standardized diagnostic pathways.

Subject of Research: Diagnostic performance of D-dimer and risk scoring in acute aortic dissection

Article Title: Low aortic dissection detection risk scores and pretest probability–dependent diagnostic value of D-dimer in acute aortic dissection

Article References: Durmaz, D., & Beyoğlu, R. (2026). Low aortic dissection detection risk scores and pretest probability–dependent diagnostic value of D-dimer in acute aortic dissection. Frontiers in Medicine, 13, Article 2001560. https://doi.org/10.3389/fmed.2026.2001560

Image Credits: AI Generated

DOI: 10.3389/fmed.2026.2001560

Keywords: acute aortic dissection, aortic dissection detection risk score, d-dimer, computed tomography angiography, diagnostic accuracy, emergency medicine, likelihood ratio, bayesian analysis, post-test probability, pretest probability, sensitivity and specificity, case-control study, thoracoabdominal cta, biomarker testing, vascular emergency, rule-out strategy, false negative