A controlled biomechanical investigation conducted by researchers at the BioRobotics Institute of Scuola Superiore Sant’Anna has revealed that semi-active upper-limb occupational exoskeletons can significantly slow the progression of muscular and cardiovascular fatigue during sustained overhead labor. Publishing their findings in the journal Wearable Technologies, the scientific team established that wearable robotic assistance curtailed the progressive decline of electromyographic median frequency in primary shoulder flexor muscles by up to 67 percent during an uninterrupted overhead task. Concurrently, the mechanical intervention yielded a 43 percent attenuation in the accumulation rate of cardiovascular exertion compared to unassisted overhead exertion.
Work-related musculoskeletal disorders represent the primary etiology of occupational morbidity across Europe, documented to compromise the health of roughly 30 to 56 percent of the industrial labor force. Among these disorders, localized pathologies of the shoulder complex and glenohumeral joint demonstrate exceptional prevalence among manual industrial workers whose routine tasks require static or repetitive arm elevation. Beyond physical impairment and diminished quality of life, the macroscopic socioeconomic fallout of these chronic disorders accounts for an estimated 2.5 percent of the European Union’s total gross domestic product through operational productivity deficits. For industrial employers, this burden manifests through direct compensation outlays and substantial indirect expenditures associated with operational downtime, work disruptions, elevated worker turnover, and continuous healthcare interventions.
Sustained overhead postures impose demanding mechanical and physiological stresses upon the human upper extremities by mandating prolonged isometric muscle contractions without sufficient rest periods. Elevated humeral postures markedly increase intramuscular pressure within the shoulder girdle, compressing microvascular structures and impairing localized blood circulation. Concurrently, the systemic physiological demands of maintaining awkward anti-gravitational postures impose a notable operational burden upon the cardiovascular system, leading to elevated heart rates and systemic tiredness. While passive and semi-active occupational exoskeletons have gained industry traction to alleviate mechanical shoulder strain, previous biomechanical evaluations have predominantly quantified instantaneous reductions in muscle activity rather than documenting how wearable assistance alters the continuous progression of physiological fatigue across time.
To rigorously examine fatigue progression under controlled loading profiles, the research team analyzed the performance of the H-PULSE semi-active upper-limb exoskeleton during a standardized overhead operation. The examined device incorporates an ergonomic wearable vest functioning as a physical human-robot interface, coupled with an articulated kinematic chain with passive degrees of freedom that align with the user’s shoulder flexion and extension axes. Assistive torque is provided to each arm through a dedicated bilateral mechanical actuation housing equipped with internal spring mechanisms. The device is calibrated to produce an angle-dependent torque trajectory that mirrors natural gravitational loading on human arms, supplying maximal anti-gravitational torque at approximately 90 degrees of humeral elevation and diminishing to zero torque when arms hang parallel to the trunk. Internal servomotors driving precision spindle assemblies permit dynamic pretensioning of the internal springs, yielding adjustable peak assistive torques between 4.5 and 6 Newton-meters across three pre-configured operational support states designated as low, medium, and high assistance.
The experimental investigation recruited ten healthy, right-handed male volunteers presenting a mean age of 28.5 years with a standard deviation of 2.5 years. Conducted in accordance with the ethical tenets of the Declaration of Helsinki following formal clearance by the local Institutional Review Board, the protocol accounted for individual anthropometric variability among participants to determine baseline arm mass and estimated center-of-mass positions. These individual biomechanical dimensions dictated the theoretical gravitational torque exerted on each participant’s glenohumeral joint during 90-degree flexion. Across the subject cohort, the configured assistive profiles provided distinct relative proportions of anti-gravitational support: the low assistance setting supplied approximately 46 to 47 percent gravitational compensation, the medium level delivered between 51 and 53 percent support, and the high setting imparted roughly 55 to 57 percent shoulder joint offloading, with slight differences observed between the left and right upper limbs.
The experimental procedure engaged each participant in a simulated industrial workflow involving continuous overhead screwing and unscrewing of mechanical hardware mounted to an overhead shelf fixture. The trial commenced with an initial two-minute static baseline interval where subjects remained standing upright with arms at rest parallel to the torso. Participants subsequently completed a continuous six-minute execution phase using an Allen key at a self-directed, steady tempo, sustaining both arms overhead with shoulder and elbow angles flexed at roughly 90 degrees. Each subject performed this standardized cycle across four distinct experimental states: an unassisted baseline condition with zero external support, followed by trials under low, medium, and high assistance configurations. To prevent physiological fatigue carryover from confounding consecutive measurements, the experimental design enforced mandatory ten-minute passive rest intervals between experimental conditions, a duration verified as sufficient to restore baseline physiological parameters.
Physiological monitoring relied on synchronized multi-channel electromyography and single-lead electrocardiography recorded at a continuous sampling frequency of 1000 Hertz. Surface electromyographic signals were acquired bilaterally over the skin of the anterior deltoid and posterior deltoid muscles using pre-gelled silver and silver-chloride bipolar surface electrodes arranged in accordance with SENIAM recommendations. The raw electromyographic recordings underwent conditioning via fourth-order zero-lag Butterworth band-pass filtering between 10 and 450 Hertz alongside notch filtering at 50 Hertz to eliminate mains interference. To monitor cardiovascular responses, an electrocardiographic recording electrode was positioned over the left pectoralis major muscle, with signals processed through a second-order Butterworth filter bounded from 0.5 to 40 Hertz. Active muscular engagement was demarcated from the moment of initial arm elevation through the complete six-minute task window to arm lowering, using right anterior deltoid activity as a temporal benchmark.
Signal parameterization subdivided active trial periods into five-second sequential epochs analyzed with four-second sliding temporal windows exhibiting an 80 percent mutual overlap. To assess peripheral muscular fatigue, electromyographic epochs were transformed into single-sided power spectra via fast Fourier transformation with applied Hanning windowing to minimize spectral leakage, from which the median frequency was derived. Progressive neuromuscular fatigue was characterized by a distinct leftward shift of the power spectrum toward lower frequencies, reflecting reduced muscle fiber conduction velocities. Cardiovascular metrics were computed by identifying electrocardiographic R-peaks and extracting consecutive R-R beat intervals to establish instantaneous heart rate and heart rate variability metrics, including the root mean square of successive differences and the ratio of low-frequency to high-frequency spectral power. Signal trends were linearized via least-squares regression to compute parameters including relative metric change over time, regression slope indicating rate of change, and baseline regression intercept values.
Electromyographic findings revealed that wearing the exoskeleton significantly mitigated the progression of localized muscle exhaustion, displaying the most pronounced benefit within the anterior deltoid flexor muscles. In unassisted trials, median frequency profiles exhibited rapid declines over the six-minute task, confirming substantial localized fatigue development. Under high exoskeleton support, the relative drop in anterior deltoid median frequency decreased by 64 percent on the left side compared to the unassisted state, achieving strong statistical significance, while right anterior deltoid relative decline dropped by roughly 37 percent. Linear regression slope evaluations demonstrated that high assistance reduced the rate of anterior deltoid median frequency decline by up to 67 percent on the left shoulder and 40 percent on the right. In contrast, posterior deltoid muscles exhibited weaker, less uniform responses; only the left posterior deltoid demonstrated modest, statistically significant alterations in median frequency slope under maximum assistance, whereas the right posterior deltoid showed no significant alterations across assistance levels.
Cardiovascular monitoring demonstrated that wearing the exoskeleton induced marked systemic cardiovascular relief compared to unassisted labor, though variation among the three assistive tiers produced subtle physiological differences. In unassisted conditions, subjects showed steadily rising heart rate trajectories indicative of progressive cardiovascular loading. Exoskeleton usage attenuated the relative increase in heart rate by up to 40 percent across assisted trials relative to the unassisted condition, while the linear slope of heart rate escalation decreased by approximately 43 percent under wearable support. However, pairwise statistical evaluations among the low, medium, and high assistance states identified no significant differences between the three assistance profiles, demonstrating that mechanical intervention successfully suppressed systemic cardiovascular strain without exhibiting marked sensitivity to the incremental torque settings evaluated.
Heart rate variability evaluations provided complementary insight into autonomic nervous system modulation throughout task execution. Measures of the root mean square of successive differences remained stable without displaying identifiable downward drift across conditions, indicative of sustained vagal tone and parasympathetic involvement. Conversely, the spectral ratio of low-frequency to high-frequency power demonstrated progressive increases over time across all testing states, reflecting shifting autonomic equilibrium toward sympathetic dominance as physiological effort accumulated.
The biomechanical divergence between anterior and posterior deltoid responses reflects their functional division of labor during overhead manual tasks. The anterior deltoids act as primary agonist flexors directly countering gravitational downward torque to keep the arms elevated, thereby reaping substantial relief when mechanical torque supports the glenohumeral joint. Conversely, the posterior deltoids primarily fulfill joint stabilization roles, which were less directly influenced by sagittal-plane anti-gravitational torque and were potentially compensated by unmonitored muscle groups. Furthermore, the absence of marked physiological differences between assistance levels likely stems from the relatively narrow mechanical range tested, wherein peak assistive torques spanned only 4.5 to 6 Newton-meters, offloading 46 to 57 percent of gravitational weight across individuals exhibiting diverse body sizes and arm masses.
The authors acknowledged clear methodological boundaries, noting that their experimental sample comprised ten young, healthy male participants in a structured laboratory setting, which restricts direct generalization to diverse industrial workforces or extended multi-hour operational shifts. Additionally, recording electromyography from only two shoulder muscle groups leaves the compensatory dynamics of surrounding scapular stabilizers uncharacterized. The investigators emphasized that future engineering research should focus on integrating multi-modal physiological sensing directly into semi-active and active wearable frames. By embedding real-time electromyographic and heart rate monitoring, subsequent generations of industrial exoskeletons could deploy adaptive control algorithms that dynamically adjust supportive torque profiles in direct response to evolving human fatigue, creating personalized ergonomic interventions that maximize worker protection during demanding overhead occupational tasks.
Subject of Research: Physiological fatigue evaluation of upper-limb occupational exoskeleton assistance during simulated overhead work
Article Title: Evaluation of fatigue progression during overhead tasks and the effects of exoskeleton assistance
Article References: Zakir, S., Grazi, L., Giovacchini, F., Vitiello, N., Trigili, E., & Crea, S. (2025). Evaluation of fatigue progression during overhead tasks and the effects of exoskeleton assistance. Wearable Technologies, 6, Article e23. https://doi.org/10.1017/wtc.2025.10008
Image Credits: AI Generated
Keywords: occupational exoskeletons, electromyography, median frequency, muscle fatigue, cardiovascular strain, heart rate variability, anterior deltoid, posterior deltoid, ergonomics, biomechanics, overhead work, musculoskeletal disorders, wearable robotics, physical strain, spectral analysis, human-robot interaction